 SG-34F
"HOCKEY PUCK" SOLID STATE RELAY 40 THRU 80 AMPS 48 TO 530 VRMS
FEATURES * * * * * * * Photo isolation Up to 1200V blocking voltage Both zero cross or random turn-on High surge capability Built-in snubber UL, CUR file E43203 SCR Output Circuitry INPUT Type
Control Voltage Range Turn On Voltage Turn Off Voltage Max. Input Current Max. Reverse Voltage DC Input 3 to 32 VDC 3 VDC max. 1 VDC min. 25 mA at 32 VDC -32 VDC AC Input 90 to 280 VAC 90 VAC max. 10 VAC min. -
OUTPUT
Type Output Voltage Range Blocking Voltage Max. Leakage Current (off) Max. Voltage Drop (at rated current) Max. Turn-On Time 240 48 to 280 VAC 600 Vpk 5 mA 380 48 to 400 VAC 800 Vpk 5 mA 1.7 VRMS Random Turn On (DC input): 1 ms Zero Cross Turn On (DC input): 1/2 cycles + 1 ms AC Input: 20 ms DC Input: 1/2 cycle + 1 ms AC Input: 40 ms 500 V/us 480 48 to 530 VAC 1200 Vpk 5 mA
Max. Turn-Off Time
Min. Off-State (dv/dt)
GENERAL
Dielectric Strength Insulation Resistance Max. Capacitance (in/out) Ambient Temperature 4000 Vrms min. (at 50/60 Hz, 1 min.) 1000 Min. (at 500 VDC) 8 pf Operating: -30C (-22F) to 80C (176F) Storage: -30C (122F) to 100C (212F) Panel Mount Termination Weight Screw 88g
7/16/08W
SG-34F
RELAY ORDERING DATA SG-34F
MODEL
D
INPUT VOLTAGE D: 3 to 32 Vdc A: 90 to 280Vac*
240
OPERATING VOLTAGE RANGE 240: 48 to 280 Vac 380: 48 to 400 Vac 480: 48 to 530 Vac
A
LOAD TYPE A: AC LOAD
40
LOAD CURRENT 40: 50: 60: 70: 80: 40A 50A 60A 70A* 80A*
Z
S
L
LED INDICATOR NIL: no LED L: with LED (not for AC input type)
ZERO CROSS OUTPUT DEVICE OR RANDOM Z: Zero cross turn on P: Random turn on (not available on 480V version) S: SCR
*UL pending
MECHANICAL DATA
Outline Dimensions Mounting
1.870 [47.5]
2-M.157 [M4.0]
2-M.118 [M3.0]
.795Max [20.2]
.902Max [22.9]
Wiring Diagram
Load power supply
Load
1.870 [47.5]
2-O.177 [O4.5]
LOAD 1 2
4
1.00 [25.4] .449 [11.4]
1
1.098 [27.9] 1.799MAX [45.7]
(~) (-)
(~) (+)
4
INPUT
3
3
1.743 [44.26] 2.299MAX [58.4]
2
input control signal
.323 [8.2]
Dimensions in inches with metric equivalents in parentheses. Tolerance: .010"
INSTALLATION
1. When mounting the relays side by side, provide a space equivalent to the width of a single SSR between two adjacent SSRs. Otherwise, reduce the load current flow to 1/2 to 1/3 of the rated current. When mounting relays on heat sink surface, first apply a heat conductive grease to the metal back surface of the SSR. Press the SSR firmly onto the heat sink to ensure a good seal. Screw the SSR down to the heat sink. Next, wire the screw terminals and securely tighten the screws.
PRECAUTIONS
1. Before connecting a load that generates a high surge current, such as a lamp load to the SSR, make sure that the SSR can withstand the surge current of the load. The product data sheet shows the non-repetitive peak value of the surge current that flows through the SSR. Normally, use 1/2 of the non-repetitive peak surge current as the standard value. If a surge current exceeding that value is expected, connect a quick-blowing fuse to protect the SSR.
2.
2.
3.
7/16/08W
SG-34F
CHARACTERISTIC CURVES
4
.
7/16/08W


▲Up To Search▲   

 
Price & Availability of SG-34FA240A40PSL

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X